• Professional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication Protocol
  • Professional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication Protocol
  • Professional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication Protocol
  • Professional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication Protocol
  • Professional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication Protocol
  • Professional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication Protocol

Professional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication Protocol

Metal Coating: Copper
Mode of Production: SMT
Layers: Double-Layer
Base Material: FR-4
Certification: RoHS, CCC, ISO
Customized: Customized
Samples:
US$ 50/Set 1 Set(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
S10A01
Condition
New
Trademark
Elechico
Origin
China
HS Code
8537101190
Production Capacity
50000 Pieces Per Month

Product Description

This single-phase variable-frequency driver is one of the single-phase power supply series.Maximum input current is 10A. Rated input voltage is AC220V 50/60Hz.This variable frequency driver is controlled by a position sensorless 180 degree sine wave vector and driven by Control of BLDC Compressor.It has abnormal bus voltage and the compressor lack of phase protection, IPM module temperature protection, compressor over-current protection and other functions.The customer only needs to control the logic of the product, use standard RS-485ModBus communication to set the target frequency and read the inverter state. So it is very easy to control the compressor safely and efficiently. This controller can provides signal of DC365V and VSP to control the DC fan.
The main specifications of S10A01 are as follows: 
Operating temperature range -20 - 60ºC
Humidity < 95% and non-condensed state
Class of pollution Max 2
Input maximum current 10A
Input maximum power 2.2kw  @220V AC
Input voltage Single phase standard voltage 220 V 50 / 60 Hz, operable voltage 170-265 V
Output Hz 15-120Hz (ultimately according to the specification of the compressor)
Carrier frequency 5.0kHz (adjustable according to compressor noise)
PFC PF value (0.90-0.99)
Communication Standard RS485 isolation design, baud rate 1200bps
LED green (one) 5V power indicator
High-pressure switch (input)* -
Program update terminal (input)* Program update using
Temperature sensor (input) * -
 
No. Name Application Remarks
  L,N AC power input (connect to filter band L1-out and N1-out ) Ø4 round wiring terminal (AWG12)
  CN485 RS485 communication XH3 terminal (AWG24)
  CN-COMP U\V\W\output connected compressor(Forbidden wrong connected) Ø4 round wiring terminal (AWG12)
  CN-FAN Connected DC fan (the terminals sequence:DC+,GND,15V,VSP,FB )  
  CN-PRM Initial program burning port XH5 terminal (AWG24)
  CN-BL BootLood function Updates the program and EPPROM XH4 terminal (AWG24)

The communication between S10A01 and outdoor main control board can be separated by RS485ModMUS (optional) or RS232 (optional).Considering the requirement of universality, the default communication mode of inverter is RS485 ModMUS which communication protocol is the standard Modbus communication protocol, and the baud rate is 1200bps.The S10A01 is slave computer, and the upper computer (outdoor system main control board) is the host. The description of the communication agreement can be provided separately by contacting our company. 
 
No. Fault content Fault description Y/ N
B0 IPM over current protection Out of IPM hardware loop setting (DC peak) YES
B1 Compressor running out of step Compressor out of step due to sudden change of load YES
B3 Compressor out of phase Any of phase out of for compressor U\V\W YES
B4 Under voltage protection DC bus voltage is less than 210V YES
B5 Over voltage protection DC bus voltage is higher than 435V YES
B6 The radiator temperature is too high The radiator temperature exceeds the set value No
B7 Abnormal radiator sensor Short circuit or break of radiator sensor No
B8 Abnormal communication The upper computer communication data cannot be received for 120 seconds continuously YES
B9 Abnormal AC phase or CT Input power under phase or abnormal AC current YES
B10 High AC current protection AC current exceeds the set protection value YES
B11 AC voltage is too low AC voltage is lower than the set value No
B12 High voltage switch protection High voltage switch interface is disconnected Optional
B13 IPM over temperature protection IPM over temperature protection YES
B14 Compressor over current protection Compressor current exceeds set value Optional
B15 APFC protection APFC protection temperature output exceeds set value No
B21 EPPROM fault EPPROM fault YES
B24 Outer fan 1 fault Rotate speed fault of fan 1 YES
B25 Outer fan 2 fault Rotate speed fault of fan 2 YES

Professional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication ProtocolProfessional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication ProtocolProfessional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication ProtocolProfessional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication ProtocolProfessional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication ProtocolProfessional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication ProtocolProfessional DC Inverter Control Circuit Board Printed Circuit Boards PCB Assembly for Single Phase Inverter Heat Pump Water Heater, with Communication Protocol

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
185
Year of Establishment
2003-01-22