Customization: | Available |
---|---|
Metal Coating: | Copper |
Mode of Production: | SMT |
Still deciding? Get samples of US$ 55/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Description | |
CC911A controller for desiccant and dehumidifier heat pump unit | |
with RS485 & WiFi, remote control receiver board. Fan speed can be set. Can match with a DC fan | |
with an LCD display and a remote control | |
Features | |
For industrial heat pump all in one type | |
Air source | |
Control Compressor, Electronic heater, Fan motor, Water circular pump, Boiler…etc | |
Specification | |
Operating voltage | AC (0.85-1.15) 220V/50Hz |
Number of compressor | One compressor control |
Indoor temperature sensor | B3470-R25=5K±1% |
Evaporator temperature sensor | B3470-R25=5K±1% |
Humidity sensor | ±5%RH(within range of 10%RH-90%RH) |
Temperature control accuracy | ±1ºC (using precision resistance box). |
Measurement accuracy of the sensor | ±1.5ºC |
Humidity sensor accuracy | ± 5%RH, can be calibrated to ± 2%RH (10%-90% RH range) through parameters |
Storage temperature range | Minus 20ºC to 80ºC |
Humidity specifies the humidity range | 1%RH-99%RH |
In heating mode, set the set temperature required by the customer in the set temperature range | 18ºC-30ºC |
Mode Selection | Independent dehumidification mode |
Independent heating mode | |
Dehumidification + heating mode | |
Air supply mode | |
Control Logic | Hot water pump control |
Boiler starting signal | |
How to control the fan unit ? | |
Control Function | Defrosting |
Timer | |
Power off memory | |
Emergency on/off | |
Mode switch selection | |
Self detection | |
System protection and error codes | Room temperature sensor failure |
Evaporator sensor fail | |
Humidity sensor failure | |
High pressure protection | |
Low pressure protection | |
Communication failure | |
Water flow protection | |
Phase-sequence protection | |
Overheat protection | |
Operation lamp | |
How to use an LCD display ? | Parameter codes on LCD display panel: C1 to C20 |
How to inquire and set a parameter ? | |
Real-time clock setting | |
Lock key and unlock | |
Mode switching | |
To set timer time and on/off | |
How to use a remote control ? | Switching between on/off, adjust the setting humidity, temperature and wind speed |
EEV | 24 hour cycle Timing ON/OFF function |
WiFi and Smart Life | Apple or Android system |
Software registration and configuration | |
How to configure the WIFI module ? | |
How to operate the software function ? | |
Product list | Main board (1) + LCD display (1) + Remote control(1)+ Infra receiver board (1) + Connection wires (1) + Humidity sensor (1) + Temp.sensors (4) + Transformer (1) |