• DC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower Unit
  • DC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower Unit
  • DC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower Unit
  • DC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower Unit
  • DC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower Unit
  • DC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower Unit

DC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower Unit

Customized: Customized
Certification: RoHS, CCC, ISO9001, CE
Brand: Elechico
Display Type: LCD
Product Name: Air Conditioner Control Board
Application: Commercial Air Conditioner Unit
Samples:
US$ 300/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
CC878
Power Supply
Power Supply 220VAC/50Hz
Trademark
Elechico
Origin
China
HS Code
8537101190
Production Capacity
50000

Product Description

ELECHICO has completed the research and development of single-phase and three-phase full series inverter compressor control products, and widely used in heat pump, air conditioning, swimming pool machine, refrigeration units and other industries.

 

Features

Staggered parallel PFC design

Built-in capacitor for convenient installation 

Two stage EMC filtering 

Supporting central air conditioner of VRF one to four 

 

Parameters

 

Model

T12A01 

T18A01

Application 

5-7HP

8-10HP

Input voltage

380V AC

380V AC

Input max.A

12A

18A

Input max.Power

7.0Kw

10.0Kw

Size(L*W*H)mm

190*210*114

190*210*136

Operating Temp Range

-20ºC-60ºC

 


Description and Function:
S16A00(3.5kw)
180 °sinusoidal DC INVERTER DRIVER
IPM temperature protection
Input maximum power :3.5kw 220V AC
Over current protection of compressor
Input maximum current: 16.0A
Compressor drive protection
Input voltage: Single phase standard voltage 220 V 50 / 60 Hz, operable voltage 170-265 V
Communication failures
Output Hz: 15-120Hz (ultimately according to the specification of the compressor)
DC bus voltage protection
Carrier frequency: 5.0kHz (adjustable according to compressor noise)
DC bus over voltage protection
PFC: PF value (0.90-0.99)
AC over current protection
Communication: Standard RS485 isolation design, baud rate 1200bps
Over power protection of compressor
 
Technical parameters:
Operating temperature range
-20 - 60ºC
Humidity
< 95% and non-condensed state
Class of pollution
Max 2
Input maximum current
16.0A
Input maximum power
3.5kw @220V AC
Input voltage
Single phase standard voltage 220 V 50 / 60 Hz, operable voltage 170-265 V
Output Hz
15-120Hz (ultimately according to the specification of the compressor)
Carrier frequency
5.0kHz (adjustable according to compressor noise)
PFC
PF value (0.90-0.99)
Communication
Standard RS485 isolation design, baud rate 1200bps
LED green (one)
5V power indicator
High-pressure(Spare)
Access to isolated high voltage switch signal, first time off compressor
Program update terminal (Spare)
Program update using
Temperature sensor (Spare)
Reserved a port of temperature sensor for venting temperature protection of the compressor
DC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower UnitDC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower UnitDC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower Unit
DC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower UnitDC Inverter Control Board PCBA for Air Conditioner and Warm Air Blower Unit

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now