Customization: | Available |
---|---|
Customized: | Customized |
Certification: | RoHS, CCC, ISO9001, CE |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ELECHICO has completed the research and development of single-phase and three-phase full series inverter compressor control products, and widely used in heat pump, air conditioning, swimming pool machine, refrigeration units and other industries.
Features
Staggered parallel PFC design
Built-in capacitor for convenient installation
Two stage EMC filtering
Supporting central air conditioner of VRF one to four
Parameters
Model |
T12A01 |
T18A01 |
Application |
5-7HP |
8-10HP |
Input voltage |
380V AC |
380V AC |
Input max.A |
12A |
18A |
Input max.Power |
7.0Kw |
10.0Kw |
Size(L*W*H)mm |
190*210*114 |
190*210*136 |
Operating Temp Range |
-20ºC-60ºC |
S16A00(3.5kw)
|
180 °sinusoidal DC INVERTER DRIVER
|
IPM temperature protection
|
Input maximum power :3.5kw 220V AC
|
Over current protection of compressor
|
|
Input maximum current: 16.0A
|
Compressor drive protection
|
|
Input voltage: Single phase standard voltage 220 V 50 / 60 Hz, operable voltage 170-265 V
|
Communication failures
|
|
Output Hz: 15-120Hz (ultimately according to the specification of the compressor)
|
DC bus voltage protection
|
|
Carrier frequency: 5.0kHz (adjustable according to compressor noise)
|
DC bus over voltage protection
|
|
PFC: PF value (0.90-0.99)
|
AC over current protection
|
|
Communication: Standard RS485 isolation design, baud rate 1200bps
|
Over power protection of compressor
|
Operating temperature range
|
-20 - 60ºC
|
Humidity
|
< 95% and non-condensed state
|
Class of pollution
|
Max 2
|
Input maximum current
|
16.0A
|
Input maximum power
|
3.5kw @220V AC
|
Input voltage
|
Single phase standard voltage 220 V 50 / 60 Hz, operable voltage 170-265 V
|
Output Hz
|
15-120Hz (ultimately according to the specification of the compressor)
|
Carrier frequency
|
5.0kHz (adjustable according to compressor noise)
|
PFC
|
PF value (0.90-0.99)
|
Communication
|
Standard RS485 isolation design, baud rate 1200bps
|
LED green (one)
|
5V power indicator
|
High-pressure(Spare)
|
Access to isolated high voltage switch signal, first time off compressor
|
Program update terminal (Spare)
|
Program update using
|
Temperature sensor (Spare)
|
Reserved a port of temperature sensor for venting temperature protection of the compressor
|