Customization: | Available |
---|---|
Metal Coating: | Copper |
Mode of Production: | SMT |
Still deciding? Get samples of US$ 300/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
13 kw and 17kw three phase of inverter compressor driver board
ELECHICO has completed the research and development of single-phase and three-phase full series inverter compressor control products, and widely used in heat pump, air conditioning, swimming pool machine, refrigeration units and other industries.
Features
Using Infineon PIM big power module
DC overvoltage and undervoltage protection, module overtemperature
Compressor over-power and under-phase protection function
Two stage EMC filtering
Supporting central air conditioner of VRF one to four
Parameters
Model |
T23A01 |
T30A01 |
Application |
12HP |
16HP |
Input voltage |
380V AC |
380V AC |
Input max.A |
23A |
30A |
Input max.Power |
13Kw |
17Kw |
Size(L*W*H)mm |
190*210*216 |
190*210*216 |
Operating Temp Range |
-20ºC-60ºC |
ELECHICO has completed the research and development of single-phase and three-phase full series inverter compressor control products, and widely used in heat pump, air conditioning, swimming pool machine, refrigeration units and other industries.
Features
Staggered parallel PFC design
Built-in capacitor for convenient installation
Two stage EMC filtering
Supporting central air conditioner of VRF one to four
Parameters
Model |
T12A01 |
T18A01 |
Application |
5-7HP |
8-10HP |
Input voltage |
380V AC |
380V AC |
Input max.A |
12A |
18A |
Input max.Power |
7.0Kw |
10.0Kw |
Size(L*W*H)mm |
190*210*114 |
190*210*136 |
Operating Temp Range |
-20ºC-60ºC |
Model | Description | Protective Functions |
T12A02 (6.5kw) | 180 °sinusoidal DC INVERTER DRIVER | IPM temperature protection |
Input maximum power :6.5kw 380V AC | Over current protection of compressor | |
Input maximum current: 12A | Compressor drive protection | |
Input voltage: Three phase standard voltage 380 V 50 / 60 Hz, operable voltage 320-460 V | Communication failures | |
Output Hz: 15-120Hz (ultimately according to the specification of the compressor) | DC bus voltage protection | |
Carrier frequency: 5.0kHz (adjustable according to compressor noise) | DC bus over voltage protection | |
PFC: PF value (0.90-0.99) | AC over current protection | |
Communication: Standard RS485 isolation design, baud rate 1200bps | Over power protection of compressor |
CC902 multi-function heating water heat pump Inverter Controller
Measuring range
|
-30°C~99°C
|
Controlling range
|
-30°C~99°C;
|
Temperature control Accuracy
|
+/-1 Celsius
|
Mounting size
|
210*134*34mm
|
Power supply
|
380 ±10%(VAC), 50/60Hz
|
Power consumption
|
<12W
|
Storage temperature
|
-25°C~50°C
|
Senor type
|
NTC(5KΩ/25°C,B value 3470K;50K/25°C, B value 3490K)
|
Relay output capacity
|
10A/240VAC
|
15A/250VAC
|
|
Product list
|
Main-board(1pcs)
|
Color touch display(1pcs)
|
|
Inverter driver board(1pcs)
|
|
Filter board(1pcs)
|
|
Connect wire (2pcs)
|
|
Temp. sensor(11pcs)
|
1
|
Color touch display, quick parameter setting, easy operation.
|
|||
2
|
Intelligent defrost control mode.
|
|||
3
|
Auto restart function Fan motor optional: AC/DC
|
|||
4
|
EEV and EVI control function
|
|||
5
|
Work modes: Cooling mode, heating mode, DHW and floor heating.
|
|||
6
|
Swimming pool, hot water or HVAC are optional.
|
|||
7
|
The product has built-in Wi-Fi module, which can realize remote control of the device through mobile APP.
|
|||
8
|
Thirteen way control output:
|
BTW water pump
|
DHW pump
|
4-way valve
|
High fan motor
|
Low fan motor
|
EVI valve
|
||
3-way valve
|
BTW electric heating
|
DHW electric heating
|
||
Crankshaft electric heating
|
Solar water pump
|
Solar steering pump
|
||
Plate heat exchanger electric heating
|
…
|
|||
9
|
Eight way sensor input:
|
Inlet water temperature
|
Outlet water temperature
|
Ambient temp. sensor
|
Coil temperature
|
Exhausted gas temperature
|
Suction temp. sensor
|
||
Outlet water temperature
|
Outlet water temperature
|
…
|