Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler

Product Details
Customization: Available
Metal Coating: Copper
Mode of Production: SMT
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
185
Year of Establishment
2003-01-22
  • Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
  • Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
  • Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
  • Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
  • Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
  • Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
Find Similar Products

Basic Info.

Model NO.
CC1076
Layers
Double-Layer
Base Material
FR-4
Certification
RoHS, CCC, ISO
Customized
Customized
Condition
New
Trademark
Elechico
Origin
China
HS Code
8537101190
Production Capacity
50000 Sets Each Year

Packaging & Delivery

Package Size
30.00cm * 20.00cm * 20.00cm
Package Gross Weight
7.000kg

Product Description

Product Description

Founded in Foshan, China in 2003, Guangdong Chico Electronic Inc. is an advanced technology manufacturer and specializes in solution for intelligent control system in multiple industries.We operate two quality certified factories in both Foshan and Heyuan,China and have introduced a series of advanced equipment including automated AOI machine, SMT machine, automated assembly machine, FCT machine and so on.

* One-stop service from designing, manufacturing and testing.

* The competitive quality, the moderate price and the promptest delivery.

* A talented team of 60 experienced engineers continually raises the bar for the future, dedicating millions of RMB annually to research and development.

* Committed to improving product quality.Our operation is ISO 9001:2000-certified and product are CE- and RoHS-marked.

Over the years, our technology has evolved and our company has grown, but our goal remains the same that is"quality based, technology leaded and customers centered". We would like to creat a beautiful electronic industry with you in the future
 

             10KW three phase DC inverter four system heat pump controller board

 

ELECHICO has completed the research and development of single-phase and three-phase full series inverter compressor control products, and widely used in heat pump, air conditioning, swimming pool machine, refrigeration units and other industries.

 

Features

Staggered parallel PFC design

Built-in capacitor for convenient installation 

Two stage EMC filtering 

Supporting central air conditioner of VRF one to four 
 

Model T18A01
Application  8-10HP
Input voltage 380V AC
Input max.A 18A
Input max.Power 10KW
Size (L*W*H) mm 190*210*136
Operating Temp. Range minus 20ºC to 60ºC
 
Model Description Protective Functions
T18A02
( 10KW )
180 °sinusoidal DC INVERTER DRIVER IPM temperature protection
Input maximum power :10kw 380V AC Over current protection of compressor
Input maximum current: 18A Compressor drive protection
Input voltage:  Three phase standard voltage 380V 50/60 Hz, operable voltage 320-460V Communication failures
Output Hz: 15-120Hz (ultimately according to the specification of the compressor) DC bus voltage protection
Carrier frequency: 5.0KHz (adjustable according to compressor noise) DC bus over voltage protection
PFC: PF value (0.90-0.99) AC over current protection
Communication: Standard RS485 isolation design, baud rate 1200bps Over power protection of compressor
CC1076 four system DC inverter controller for low temperature water heater and cooler

CC1076 Series heat pump Inverter Controller is designed for controlling commercial heating or cooling heat pump with DC

inverter compressor driver control board.

The biggest advantage of ELECHICO is our ability to customize products for our customers to meet their diverse

requirements.

We are mainly exporting OEM/ODM services.
Technical parameters:
 
Measuring range minus 30 to 99 °C
Controlling range minus 30 to 99 °C
Temperature control Accuracy +/-1 Celsius
Mounting size 210*134*34 mm
Power supply 380 ±10%(VAC), 50/60Hz
Power consumption <12W
Storage temperature minus 25°C~50°C
Sensor type NTC (5KΩ/25°C,B value 3470K;50K/25°C, B value 3490K)
Relay output capacity 10A/240VAC
15A/250VAC
Product list Main-board (1pcs)
Color touch display (1pcs)
Inverter driver board (1pcs)
Filter board (1pcs)
Connect wire  (2pcs)
Temp. sensor (11pcs)
Model selector switch
SW1 DIP switch 1 DIP switch 2 DIP switch 3 and 4 DIP switch 5 DIP switch from 6 to 8
ON Single-phase Dual systems Model selection Direct heating cycle The choice of address bits
OFF Three-phase Four systems Single cycle
How to select model type ?
DIP switch 3 DIP switch 4 Model selection
OFF OFF CCHP system ( combined cooling heating & power )
OFF ON Single DHW
ON OFF Cooling + heating
ON ON CCHP system ( combined cooling heating & power )

Features:
 
1 Color touch display, quick parameter setting, easy operation.
2 Intelligent defrost control mode.
3 Auto restart function Fan motor optional: AC/DC
4 EEV and EVI control function
5 Work modes: Cooling mode, heating mode, DHW and floor heating.
6 Hot water or HVAC are optional.
7 The product has built-in Wi-Fi module, which can realize remote control of the device through mobile APP.
8 Thirteen way control output: BTW water pump DHW pump 4-way valve
High fan motor Low fan motor EVI valve
3-way valve BTW electric heating DHW electric heating
Crankshaft electric heating Solar water pump Solar steering pum
Plate heat exchanger electric heating
9 Eight way sensor input: Inlet water temperature Outlet water temperature Ambient temp.sensor
Evaporator temperature Discharge temperature Suction temp.sensor
Outlet water temperature Outlet water temperature
10 Function of system protection: 1. The communication failure code 09E
2. Three-phase protection with error code 00E ( This function is available when the three-phase model is selected )
3. Ambient temperature failure 12E
4. Water tank temperature failure 15E
5.Water inlet temperature failure 26E
6. Water outlet temperature failure 13E
7. Evaporator temperature failure 1#/2#/3#/4#
8. Suction temperature failure 1#/2#/3#/4#
9. Discharge temperature failure 1#/2#/3#/4#
10.Temperature failure 1#/2#/3#/4# after throttling (only detected for models with cooling mode)
11.System high pressure protection 1#/2#/3#/4#
12. System low pressure protection 1#/2#/3#/4#
13. Protection against discharge temperature super heat 1#/2#/3#/4#
14. Water flow switch protection 01E
15. Winter anti-freezing protection
16. Protection against the outlet water being too cold 08E in the cooling mode
17. Compressor module failure protection 1#/2#/3#/4#
18. Protection against excessive temperature difference between the water inlet and outlet
19. Failure 1#/2#/3#/4# of DC inverter module
20. Protection against excessively low ambient temperatures
21. Failure of low pressure sensor 1#/2#/3#/4#
22. 1/2 overload protection for the fan motor
23. Power off memory
24. Display the correction function through water temperature
25. Timer on/off function
26. Compulsory defrosting function
 
How to control the compressor frequency ?
Level of frequency F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Hz 40 45 52 60 65 70 75 80 85 90
 
The initial operating frequency in heating mode is controlled according to the ambient temperature and water inlet temperature.
Temperature interval Ambient temperature
Water inlet temp.  <-22ºC [-22,-15) [-15,-9) [-9,-3) [-3,4) [4,11) [11,18) [18,26) [26,35) ≥35ºC
Water inlet temp.≤10ºC F8 F9 F9 F9 F9 F8 F8 F8 F7 F6
10ºC<water inlet temp.≤20ºC F9 F9 F9 F9 F9 F8 F8 F8 F7 F6
20ºC<water inlet temp.≤32ºC F10 F10 F10 F10 F9 F8 F8 F8 F7 F6
32ºC<water inlet temp.≤38ºC F10 F10 F10 F10 F9 F8 F8 F8 F7 F6
38ºC<water inlet temp.≤43ºC F10 F10 F10 F10 F9 F8 F8 F8 F7 F6
43ºC<water inlet temp.≤48ºC F10 F10 F10 F10 F9 F8 F8 F8 F7 F6
48ºC<water inlet temp.≤56ºC F8 F8 F8 F8 F8 F8 F7 F7 F6 F5
56ºC<water inlet temp. F7 F7 F7 F7 F7 F7 F6 F6 F5 F4
 
The initial operating frequency control in cooling mode is based on the ambient temperature and inlet water temperature
Level of frequncy F1 F2 F3 F4 F5
Hz 60 65 70 75 80
           
Temperature interval Ambient temp.
Water inlet temperature Ta≤26ºC 26ºC<Ta≤30ºC 30ºC<Ta≤33ºC 33ºC<Ta≤38ºC 38ºC<Ta
Water inlet temp.≤10ºC F3 F4 F4 F4 F2
10ºC<water inlet temp.≤15ºC F4 F5 F5 F3 F3
15ºC<water inlet temp.≤20ºC F4 F5 F5 F3 F3
20ºC<water inlet temp.≤25ºC F4 F4 F4 F4 F3
25ºC<water inlet temp.≤30ºC F3 F4 F3 F4 F2
30ºC<water inlet temp.≤40ºC F2 F3 F2 F2 F1
40ºC<water inlet temp. F1 F2 F2 F1 F1
 
User's parameter
Parameter No. Parameter abbreviation Parameter name (definition) Adjustment range Initial value
P00 Hot water setting To set temperature in hot water mode 20ºC~55ºC 50ºC
P01 Hysteresis error for hot water Hysteresis error for hot water 2ºC~18ºC 5ºC
P02 Preserved   20ºC~80ºC 30ºC
P03 Make-up water due to temperature difference Set temperature for temperature difference water refill 20ºC~80ºC 43ºC
P04 To set heating Set temperature for air conditioning heating 12ºC~55ºC 50ºC
P05 To set cooling Set temperature for air conditioning cooling 10ºC~32ºC 12ºC
P06 Hysteresis error of air conditioning Hysteresis error of air conditioning heating & cooling 2ºC~18ºC 5ºC
P07 The ambient temperature at which the electric heating is allowed to turn on The ambient temperature at which the electric heating is allowed to turn on -30ºC~35ºC 5ºC
P08 Timing cycle of pump Pump timing cycle selection 0~61min 0 min
P09 Excessive temperature differentials Protection value set to prevent excessive temperature difference between inlet and outlet water temperature. 5ºC~50ºC 13ºC
 
Frequency conversion parameter table
Parameter No. Parameter abbreviation Parameter name Setting range Default Remark
H00 Frequency mode Auto frequency/manual frequency 0: auto 0: auto  
1: manual
H01 Manual frequency 1 Manual frequency 30~100Hz 50Hz  
H02 Compressor frequency 10 To set frequency F10 30~100Hz 90Hz  
H03 Compressor frequency 9 To set frequency F9 30~100Hz 85Hz  
H04 Compressor frequency 8 To set frequency F8 30~100Hz 80Hz  
H05 Compressor frequency 7 To set frequency F7 30~100Hz 75Hz  
H06 Compressor frequency 6 To set frequency F6 30~100Hz 70Hz  
H07 Compressor frequency 5 To set frequency F5 30~100Hz 65Hz  
H08 Compressor frequency 4 To set frequency F4 30~100Hz 60Hz  
H09 Compressor frequency 3 To set frequency F3 30~100Hz 52Hz  
H10 Compressor frequency 2 To set frequency F2 30~100Hz 45Hz  
H11 Initial frequency in constant temperature mode Initial frequency in constant temp. mode 30~100Hz 40Hz  
H12 How to set fan speed 6 ? Fan speed 6 300~990BPS 900BPS  
H13 How to set fan speed 5 ? Fan speed 5 300~990BPS 850BPS  
H14 How to set fan speed 4 ? Fan speed 4 300~990BPS 800BPS  
H15 How to set fan speed 3 ? Fan speed 3 300~990BPS 800BPS  
H16 How to set fan speed 2 ? Fan speed 2 300~990BPS 800BPS  
H17 How to set fan speed 1 ? Fan speed 1 300~990BPS 800BPS  
H18 How to set discharge temp. 4 ? To set set discharge temp.TP4. 50~125ºC 115ºC  
H19 How to set discharge temp. 3 ? To set set discharge temp.TP3 50~125ºC 110ºC  
H20 How to set discharge temp. 2 ? To set set discharge temp.TP3 50~125ºC 107ºC  
H21 How to set discharge temp. 1 ? To set set discharge temp.TP1 50~125ºC 105ºC  
H22 How to set discharge temp. 0 ? To set set discharge temp.TP0 50~125ºC 100ºC  
H23 Constant temp.control Choice of constant temp.control 0: without 1 Air conditioning side active
1:with
H24 Low pressure Choice with or without low pressure sensor Without / with Without  
H25 Low pressure Low pressure protection value( preserved ) 0~200KPa 5KPa The value on CC596 5-inch TFT panel*10 KPa
H26 Compensation of compressor frequency in hot water mode Compensation of compressor frequency in hot water mode -30~10 -10  
H27 Frequency of silent mode The highest frequency limited by silent mode 30~120Hz 60Hz  
H28 Mode of fan control Selection of fan control mode 0:auto 0:auto  
1: manual
H29 Manual wind speed setting Manual wind speed 300~990BPS 500BPS  
H30 Defrosting frequency     60Hz  
H31 High water temperature defrosting frequency compensation     -15Hz  
H32 Compensation value of high water temperature defrosting frequency     -7ºC  
H33 High water temperature judgment value     36ºC  

Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and CoolerCc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler
Cc1076 Four System DC Inverter Controller Board PCBA for Water Heater and Cooler

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier